PFAS Decontamination of Pipeline Systems Using Hydrogel-Assisted Sequential Cleaning Technology
-
Press Release
Share article:
Per- and polyfluoroalkyl substances (PFAS) have historically been used in a wide range of industrial applications, including certain firefighting foams, because of their exceptional chemical and thermal stability and their excellent surface-active properties. However, these same properties make PFAS compounds highly persistent and particularly challenging to remove from contaminated equipment and infrastructure.
A specific challenge arises in pipeline systems that were previously used for the transport or distribution of PFAS-containing firefighting agents. Before such infrastructure can be safely repurposed, residual PFAS contamination must be removed not only from the remaining liquid phase but also from the internal surfaces of the pipelines, where PFAS-containing residues may remain adsorbed or deposited.
Proposed Solution
To address this challenge, OKFT Kft. – a Hungarian gel pigging company – and the University of Szeged (SZTE) have jointly investigated an innovative cleaning concept combining hydrogel-based plug technology with a specially developed chemical cleaning formulation.
The fundamental difference compared with conventional flushing is that the complete pipeline volume does not need to be continuously filled with cleaning solution. Instead, the active cleaning agent is transported through the pipeline as a controlled liquid segment – or “wagon” – positioned between hydrogel plugs.
The hydrogel plugs act as mobile separation and displacement barriers, maintaining the integrity of the individual treatment zones while they travel through the pipeline. This enables the active cleaning formulation to remain concentrated at the surface being treated and substantially reduces dilution and mixing between consecutive liquid phases.
In this arrangement, the leading hydrogel plug establishes and stabilizes the treatment zone. It is followed by the specially developed chemical formulation, which interacts with the contaminated internal pipe surface and promotes the release and removal of PFAS-containing residues.
Together, the low material demand, approximately 0.20 pipeline-volume liquid requirement, 15–30-fold reduction in wastewater generation, simple preparation and on-site applicability provide a strong basis for economical scale-up and industrial implementation.
OKFT Hungary undertakes PFAS removal by the above technology in Europe and the Middle-East.
Contact: info@okft.hu and https://okft.hu